The machine is making ice, the bin is filling, and yet the day's output is short. When a buyer sends us that complaint, the first thing we time is the harvest: the few minutes when hot refrigerant gas is diverted into the evaporator so the frozen slab releases and drops. If that stage is stretched, the machine is running, drawing power and producing nothing — the most expensive state an ice machine can be in, and the easiest to miss because the fault code is silent.
![]()
During freezing, water is pumped over a nickel-plated copper mould and the growing ice grips the metal. To release it, the controller stops the pump, closes the water inlet and opens the harvest solenoid so hot discharge gas flows directly into the evaporator. The plate warms a few degrees, the bond between ice and metal breaks, the slab slides onto the grid, breaks into cubes, and the falling ice trips the curtain switch to restart freezing. If the gas is not hot enough, not flowing enough, or the ice is too thick, release slows and every cycle loses seconds. Over a day of roughly 15 to 20 minute cycles, those seconds accumulate into lost tonnage.
| What you observe | What it points to | How to test it |
|---|---|---|
| Harvest solenoid does not click | Coil failure, wiring, or a controller output that is not switching | Voltage at the coil when harvest should start; coil resistance |
| Clicks, but the hot gas line stays cool | Valve stuck closed, blocked strainer, or low charge | Feel and measure the line at the evaporator inlet |
| Line hot but plate warms slowly | Low refrigerant charge or a weak compressor | Suction and discharge pressures; current against nameplate |
| Some cubes hold on after the rest fall | Scale, worn mould surface, or ice too thick | Inspect the mould; weigh ten cubes |
| Ice drops but the cycle does not restart | Water curtain or curtain switch sticking | Swing the curtain by hand during harvest |
| Slow only in a cold room | Head pressure too low to drive hot gas | Discharge pressure converted to temperature versus ambient |
Our listings publish the freeze cycle as 15 to 20 minutes per batch on the smaller and mid-range cube machines, the ice size as 22 x 22 x 22 mm on the standard models, and the condenser type as copper fin with a copper-plated nickel ice mould. What no catalogue states is the harvest duration for your site, because it depends on ambient and head pressure. Ask for the expected harvest time for the model you are buying and record your own at commissioning — that baseline is what makes a slow harvest detectable two years later.
The choice of refrigerant also matters here. Models in our range are supplied on R404a, R507a, R134a or R22 depending on capacity and market, and the harvest behaviour differs with the pressure the system reaches: a machine running at low head pressure in a cold room has less hot gas available, which is why winter complaints and cold-store installations show up together.
How long should a harvest take? It should be a small fraction of the published 15 to 20 minute cycle. Ask for the figure for your model and record your own at commissioning.
Can a slow harvest damage the compressor? Indirectly. Long harvests mean long low-load running and repeated hot gas cycling; the compressor runs outside its efficient envelope.
Is a thicker cube better for drinks? It melts more slowly, but it also lengthens every cycle and raises energy per kilogram. Standard 22 x 22 x 22 mm cubes suit bar service well.
Why does it only happen in winter? Low ambient means low head pressure; without control, there is not enough hot gas to release the slab quickly.
If your harvest now takes noticeably longer than it did at commissioning, the machine is losing output every hour. Send us the model, the ambient temperature and your timed harvest, and we will narrow it down. See the 500–1000 kg/24h range, the 90 kg/24h bar machine, the 900 kg/24h BMC2000P, or ask our service engineers.
The machine is making ice, the bin is filling, and yet the day's output is short. When a buyer sends us that complaint, the first thing we time is the harvest: the few minutes when hot refrigerant gas is diverted into the evaporator so the frozen slab releases and drops. If that stage is stretched, the machine is running, drawing power and producing nothing — the most expensive state an ice machine can be in, and the easiest to miss because the fault code is silent.
![]()
During freezing, water is pumped over a nickel-plated copper mould and the growing ice grips the metal. To release it, the controller stops the pump, closes the water inlet and opens the harvest solenoid so hot discharge gas flows directly into the evaporator. The plate warms a few degrees, the bond between ice and metal breaks, the slab slides onto the grid, breaks into cubes, and the falling ice trips the curtain switch to restart freezing. If the gas is not hot enough, not flowing enough, or the ice is too thick, release slows and every cycle loses seconds. Over a day of roughly 15 to 20 minute cycles, those seconds accumulate into lost tonnage.
| What you observe | What it points to | How to test it |
|---|---|---|
| Harvest solenoid does not click | Coil failure, wiring, or a controller output that is not switching | Voltage at the coil when harvest should start; coil resistance |
| Clicks, but the hot gas line stays cool | Valve stuck closed, blocked strainer, or low charge | Feel and measure the line at the evaporator inlet |
| Line hot but plate warms slowly | Low refrigerant charge or a weak compressor | Suction and discharge pressures; current against nameplate |
| Some cubes hold on after the rest fall | Scale, worn mould surface, or ice too thick | Inspect the mould; weigh ten cubes |
| Ice drops but the cycle does not restart | Water curtain or curtain switch sticking | Swing the curtain by hand during harvest |
| Slow only in a cold room | Head pressure too low to drive hot gas | Discharge pressure converted to temperature versus ambient |
Our listings publish the freeze cycle as 15 to 20 minutes per batch on the smaller and mid-range cube machines, the ice size as 22 x 22 x 22 mm on the standard models, and the condenser type as copper fin with a copper-plated nickel ice mould. What no catalogue states is the harvest duration for your site, because it depends on ambient and head pressure. Ask for the expected harvest time for the model you are buying and record your own at commissioning — that baseline is what makes a slow harvest detectable two years later.
The choice of refrigerant also matters here. Models in our range are supplied on R404a, R507a, R134a or R22 depending on capacity and market, and the harvest behaviour differs with the pressure the system reaches: a machine running at low head pressure in a cold room has less hot gas available, which is why winter complaints and cold-store installations show up together.
How long should a harvest take? It should be a small fraction of the published 15 to 20 minute cycle. Ask for the figure for your model and record your own at commissioning.
Can a slow harvest damage the compressor? Indirectly. Long harvests mean long low-load running and repeated hot gas cycling; the compressor runs outside its efficient envelope.
Is a thicker cube better for drinks? It melts more slowly, but it also lengthens every cycle and raises energy per kilogram. Standard 22 x 22 x 22 mm cubes suit bar service well.
Why does it only happen in winter? Low ambient means low head pressure; without control, there is not enough hot gas to release the slab quickly.
If your harvest now takes noticeably longer than it did at commissioning, the machine is losing output every hour. Send us the model, the ambient temperature and your timed harvest, and we will narrow it down. See the 500–1000 kg/24h range, the 90 kg/24h bar machine, the 900 kg/24h BMC2000P, or ask our service engineers.